Add to Cart
Argon plant 100 Nm3/h LAr KDONAr-3200/3500/100Y Maturity Gas High Purity
Specifications:
Standard Products for Argon Plant KDONAr Series
MODEL CONTENTS | KDONAr-2500Y/1000/500Y/ 115Y | KDONAr-3200/ 150Y/4500/100Y | KDONAr-3000Y/4000/1300Y/90Y | KDONAr-3000Y/2000Y/ 3000/95Y | |
GOX/GAN/ LAr flow | Nm3/h | 2500/1000/500/115 | 1500/1500/48 | 3000/4000/ 1300/90 | 3000/2000/3000/95 |
GOX/GAN/ LAr purity | ppm | 99.6%O2/5ppmO2/ 2 ppmO2,3 ppmN2 | 99.6%O2/10ppmO2/ 99.9995% Ar | 99.6%O2/ 3ppmO2/2 ppmO2,3 ppmN2 | 99.6%O2/ 3ppmO2/ 2 ppmO2,3 ppmN2 |
GOX/GAN /LAr pressure | MPa | 0.2/0.024/ 0.3/0.16 | 0.026/0.17/ 0.018/0.16 | 0.2/0.015/ 0.3/0.16 | 0.2/0.3/0.15/0.16 |
Subcooled | ℃ | -181/38/-192/-182 | -180/38/38/-183 | -181/38/-192/ -182 | -183/-191/-18/-183 |
Typical Product: KDONAr-3200/3500/100Y Argon plant
Output, purity and pressure
| Flow (Nm3/h) | Purity | Pressure MP(G) | Subcooled(℃) |
GOX/GAN/LAr | 3200 Nm3/h /3500 Nm3/h/100 Nm3/h | 99.6% O2 /10ppmO2/ 2ppmO2,3ppmN2r | 0.018/0.015/ 0.12 | 19/19/ -181 |
Description:
The flow path of air and its products in the air separation plant usually like: air→ air filter→ air compressor→ air cooling system→ molecular sieve adsorber→ main heat exchanger→ lower column→ main condenser→ upper column→ subcooler→ main heat exchanger→ molecular sieve purification system heater→ molecular sieve adsorber→ atmosphere. We can summary the influence to the discharge pressure of air compressor from various resistances. Due to the demarcating of main condenser pressure mapping, the resistances can be roughly classified to two parts: one part is the resistance from the outlet of air compressor to the top of lower column, which can be interpreted as feed gas flow path resistance; the other part resistance is from bottom of upper column to waste nitrogen vent valve, which can be interpreted as product gas flow path resistance.
Applications:
Competitive Advantage: