
Add to Cart
Liquid nitrogen generator 3000 KDN-3000 Inert Gas GAN Nitrogen Gas
Specifications:
KDN Series Nitrogen Generator
MODEL CONTENTS | KDN-3000/190Y | KDN-3000/200 | KDN-3010-130 | KDN3200/150 | |
GAN/LIN flow | Nm3/h | 3000/190 | 3000/200L/h | 3010/130L/h | 3200/150L/h |
GAN/LIN purity | ppm | 10ppm(O2) | 99.99% | 1ppm(O2) | 10ppm(O2) |
GAN/LIN pressure | MPa | 0.3/0.2 | 1 | 0.8/0.8 | 0.7/0.7 |
Subcooled | K | 286.15/92.15 | 286.15/92.15 | 286/92.15 | 286/92.15 |
Typical Product: KDN-3000 Liquid nitrogen generator
Output, purity and pressure
| Flow (Nm3/h) | Purity | Pressure MPa(G) | Subcooled (K) |
LN | 3000 | ≤1ppm(O2) | 0.8 | 286.15 |
Description:
This plant employs a process in which the air is purified by molecular sieve, expansion turbine is provided with braking effected by fan and nitrogen is produced by means of single column with expansion accomplished through backflow. After the feed air is cleaned of dust and mechanical impurities in air filter, it is compressed in air compressor to a pressure of approx. 0.9 Mpa(G).
The compressed air is then fed into air pre-cooling system. When it is cooled to about 5℃, it becomes saturated.
The saturated and compressed air flows into switched molecular sieve adsorbers where such hydrocarbons as H2O, CO2 and C2H2 are adsorbed from the air.
A small part of purified process air is drawn out to be used as instrument air and the remainder is fed into main heat exchanger. The expanded waste nitrogen is drawn, which cooled after being expanded to a saturation temperature and moisture- bearing to a certain extent, is throttled into the bottom of nitrogen column for participation in rectification. The nitrogen gas and liquid nitrogen are then obtained at the top of nitrogen column while the saturated and oxygen-rich liquid air at the bottom of column is throttled into the evaporation side of condenser evaporator to condense the nitrogen gas at the top of column.
Oxygen-rich liquid air at the evaporation side of condenser evaporator is heated and vapored to be saturated gas by nitrogen gas at the top of column, and then it is drawn out and into cold end of main heat exchanger, after being rewarmed, it is drawn out and into turbo-expander to be expanded and refrigerated. Expanded oxygen-rich liquid air enters main heat exchanger to be rewarmed to normal temperature and to be fed out of cold box; partial gas is to be regeneration gas for molecular sieve adsorber, the rest is blowed off.
The nitrogen gas and liquid nitrogen are drawn out of the top of nitrogen column. The nitrogen gas flows out of cold box to the client with the required pressure by client after it is reheated in main heat exchanger to a normal temperature. The liquid nitrogen will be drawn out of the top of column and throttled to the required pressure and fed out of cold box to the storage tank, and is used as the spare gas of pure nitrogen equipment.
Applications:
1. Generate Vegetable Maturity Gas
2. Enrichment Gas
3. N2 Converter Rental
4. Standard Gas
5. Medical science
Competitive Advantage:
1. Our company is the biggest air separation plant design and manufacture base
2. The design philosophy of this nitrogen plant is long, stable and reliable running, economization of energy, convenient operation and maintenance.
3. The advanced design and processing software from NREC of USA is used to design the performance & passages of expander and to process the passages.
4. The five-axis simultaneously controlled machine centre imported from Sweden is available for the precision processing of 3 dimensional shrouded impeller so as to ensure the highest running efficiency and stability of expander.