Add to Cart
VPSA-1400 Nm3/h (N2) PSA Nitrogen Generator
PSA nitrogen generator
Typical Product
Output, purity and pressure
Product | Pressure ex. battery limit of plant MPa (G) | Temperature °C | Purity Index | Output Nm3/h |
Nitrogen | 0.6 | ~20 | ≥95%N2 | ≥1400 |
Instrument Air |
| ~ | Oil-free, water-free, dust-free Dew point<-50℃ |
|
Process Description:
Following goes through air buffer CG-2 after the feed air is compressed by 2 sets of compressors GA250 (airflow≥73Nm3/min, pressure≥1.0MPa). After elimination of most oil, moisture and dust in one-stage and two-stage filter, the feed air goes to refrigerating dryer with 75m3 volume, and then it enters precise filter/active carbon filter to be degreased as the residue grease content ≤0.01ppm. Then it enters PSA separation system (HYN1400 nitrogen generation unit) in which filled with adsorbent after it goes through buffer CG-8.
Process Flow Diagram
Applications:
Competitive advantage: